Level of completion

All properties in La Ville are offered in full completion in terms of exterior environment .

The exterior and vertical layout of all buildings are fully completed and include:

  • Landscaping and irrigation system
  • Pavements on alleys, roads and sidewalks, vertical and horizontal road markings
  • Street lighting and site infrastructure

All buildings are fully finished in terms of:

  • Basic load-bearing structure
  • Architecture – facade and partition walls, thermal insulation, waterproofing, installed front doors, common areas in the buildings
  • Facades
  • Installations – Heating, ventilation and air-conditioning installation without end elements (radiators and appliances) , electrical installation (wiring) , plumbing and sewerage installation .

CONSTRUCTION CONCEPT

The principles, solutions and materials laid down in the construction of La Ville are:

Structure – reinforced concrete supporting structure in accordance with European standards for building design (Euro), as used concrete class C 2 25 and C 30/37. Author of the project is the leading design company LP Arch” LTD.

Clear height of the premises from 2.73 to 3.13 m

Walls – partition – certified systems for dry construction of Knauf , adapted to heat and noise protection requirements walls – façade – Masonry wall of kermichen bricks , bilateral jointed Wienerberger Porotherm 25 N + F

Glazing – System facade aluminum frames Sch ü co AWS 70.HI (Sch ü co ADS 70.HD for entrance door with broken thermal bridge with a coefficient of thermal conductivity of the frame Uf = 1.6 W / m ² K, powder painting.

Standard double glazing:

Coefficient of thermal conductivity (EN 673): max . U = 0.5 W / (m2K)

UV (UV transmittance) – transmission of UV rays : 1.30%

Solar factor (g): 34.8

Coefficient of shading (EN 410): 0.40

Color neutral , clear

Minimum configuration :

Total thickness e o 46 mm :

– outer glass : tempered Float Glass ExtraClear Guardian SunGuard HS SN 70/37 HT or equivalent

– camera – 90% Argon – spacer with warm edging – recommended width 16 mm , minimum width 14 mm

– intermediate glass : Float Glass ExtraClear Plus

– camera – 90% Argon – spacer with warm edging – recommended width 16 mm , minimum width 14 mm

Facades – ventilated facades with thermal insulation and finishing materials, according to facade engineering 

– Thermal insulation – in accordance with thermal calculations – minimum 1 cm   

Roofs – flat roofs , – System – flat – inverted and landscaped – Thermal insulation – according to thermal calculations at least 12 cm.

Landscaping and vertical planning – designed according to the highest standards with a special dendrological project for park development, with detailed dendrological composition and planting project. 

Energy source – Natural gas ( CNG ) and electricity   

– Water supply with two types of water – for drinking and household needs with power supply from the central water supply and for irrigation needs with the use of groundwater and rainwater . 1650 m 3 

– Separate sewerage – domestic with treatment facilities .